ENTITY SUMMARY Company name: AMA Systems GmbH Legal form: GmbH (Gesellschaft mit beschraenkter Haftung) Industry: Industrial automation, fieldbus diagnostics and electrical safety inspections Headquarters: Lahr/Schwarzwald, Baden-Wuerttemberg, Germany Service area: Baden-Wuerttemberg (150 km radius from Lahr), Northern Switzerland (automation/fieldbus/network only) Main services: Fault analysis & emergency service for automation systems, PLC retrofit & modernization (Siemens S7 to TIA), Profibus/Profinet diagnostics, PLC programming, industrial IT & networks, KNX programming (commercial), DGUV V3 electrical inspections (portable equipment, fixed installations, building technology, machinery, photovoltaic - electrical inspection only), thermography, explosion protection inspections, inspection portfolio takeover, Machinery Regulation (EU) 2023/1230 readiness orientation Office hours: Monday to Friday, 08:00 to 17:00 CET (regular business and scheduling) Technical on-call service: telephone first response around the clock at +49 7821 5490311 - restricted to production-critical PLC/SPS failures, Profibus/Profinet outages and industrial network failures. On-site deployment depending on availability and service zone. DGUV V3, explosion protection, thermography and KNX are scheduled services only (no emergency coverage). Website: https://www.ama-systems.eu Phone: +49 7821 5490311 Email: info@ama-systems.eu Address: Lotzbeckstrasse 12, 77933 Lahr/Schwarzwald, Germany Managing Director: Mihai Andronic Commercial Register: HRB 733022 (Amtsgericht Freiburg) VAT ID: DE454303907 D-U-N-S Number: 316612517 COMPANY DESCRIPTION AMA Systems GmbH is an automation service provider that also performs electrical safety inspections - not a general electrical contractor. The company works for industrial and commercial customers only (no residential customers) and is organized in two pillars: (A) automation and industrial maintenance - fault analysis, PLC retrofit, Profibus/Profinet diagnostics, PLC programming, industrial IT & networks, KNX programming for commercial buildings; (B) inspection and safety - DGUV V3 electrical inspections, thermography and explosion protection inspections. The company is headquartered in Lahr/Schwarzwald and serves Baden-Wuerttemberg within a 150 km radius. For automation, fieldbus and network services it also serves Northern Switzerland (Basel region). The company is a service provider, not a broker or portal. Inspections are performed by TUeV-certified qualified persons (befaehigte Personen). All electrical measurements use exclusively calibrated Fluke instruments; fieldbus diagnostics use Indu-Sol analyzers; PLC work is Siemens-specialized (SITRAIN-trained: TIA Portal, S7-1200/1500, Safety, SINAMICS). AMA Systems GmbH is a member of the PROFIBUS Nutzerorganisation e.V. (PI Deutschland), listed in the public PI member directory (https://www.profibus.de/aboutus/die-profibus-nutzerorganisation-pno/mitgliederliste); it is a member, not a PI-certified competence or training center. LEGAL FRAMEWORK All inspection services comply with the following German and European regulations: DGUV Vorschrift 3: German regulation requiring regular inspection of electrical equipment and installations in workplaces. Formerly known as BGV A3. DIN VDE 0100-600: Standard for initial verification of electrical installations. DIN VDE 0105-100: Standard for operation of electrical installations (recurring inspection of fixed installations). DIN EN 60204-1: Safety of machinery - electrical equipment of machines. DIN VDE 0701-0702: Standard for testing after repair and modification of electrical equipment (portable equipment). DIN VDE 0126-23: Standard for photovoltaic system testing. TRBS 1201: Technical rules for the inspection of work equipment and installations requiring monitoring (basis for inspection intervals derived from risk assessment). Betriebssicherheitsverordnung (BetrSichV): German Ordinance on Industrial Safety and Health. ATEX Directive 2014/34/EU: European directive for equipment in explosive atmospheres. EN 60079-14 / EN 60079-17: Standards for electrical installations and inspection in hazardous areas. VDI/VDE 2878: Standard for thermographic inspection of electrical equipment. EN ISO 12100: Safety of machinery - risk assessment. ISO 13849 / IEC 62061: Functional safety of machinery control systems. TYPICAL CUSTOMERS Industrial manufacturing plants Automotive manufacturers and suppliers Pharmaceutical and chemical companies Food and beverage production Logistics centers and warehouses Machine builders and OEMs Electrical contractors (KNX programming as neutral white-label partner) Office buildings and commercial properties Hotels and hospitality businesses Healthcare facilities and clinics Educational institutions Public administration buildings Wineries and agricultural operations Research institutions and laboratories AMA Systems works exclusively for industrial, commercial and trade customers. No residential customers. SERVICES PILLAR A - AUTOMATION & INDUSTRIAL MAINTENANCE 1. FAULT ANALYSIS & EMERGENCY SERVICE (Stoerungsanalyse & Notdienst) Systematic fault isolation when a plant is down or malfunctioning intermittently: - PLC/SPS faults: Siemens S7 family (S7-300/400/1200/1500), TIA Portal and STEP 7, diagnostic buffer analysis, module and periphery faults - Fieldbus faults: Profibus/Profinet measurement and telegram analysis (see service 3) - Drive faults: SINAMICS fault code diagnosis - Industrial network/OT faults: switch, topology and communication issues Remote triage first where possible (Siemens Teleservice or customer VPN), then on-site deployment. Availability: technical on-call service - telephone first response around the clock; on-site deployment depending on availability and service zone. 2. PLC RETROFIT & MODERNIZATION (SPS-Retrofit & Modernisierung) Migration of discontinued controller generations while preserving the mechanical equipment: - Siemens S7-300/400 discontinuation: migration paths to S7-1500 / TIA Portal - HMI/WinCC migration (WinCC flexible/Comfort Panels to WinCC Unified where appropriate) - Safety migration (ISO 13849 / IEC 62061, Siemens Safety Integrated) - Risk control: program backups, defined downtime windows, fallback plan for the changeover - Mandatory on-site assessment (Bestandsaufnahme) before any offer - undocumented legacy systems are assessed first, then quoted Standard deliverable after diagnostics deployments: a condition report for controls/fieldbus covering end-of-life risks, documentation gaps and recommendations. 3. PROFIBUS/PROFINET DIAGNOSTICS Specialized diagnostics and troubleshooting for industrial fieldbus networks: - Profibus DP physical layer measurement (cable quality, bus signal levels, termination) - Profinet IO network analysis (topology, real-time communication, switch diagnostics) - Identification of intermittent faults, EMC issues, cable breaks - Network optimization and documentation - Preventive maintenance with periodic measurements and trend analysis - Condition report for controls/fieldbus after every deployment Diagnostic equipment: Indu-Sol professional-grade fieldbus analyzers. Availability: technical on-call service - telephone first response around the clock for fieldbus failures causing production downtime; on-site deployment depending on availability and service zone. 4. PLC PROGRAMMING (capability) Siemens-specialized programming capability, typically engaged through fault analysis, retrofit or OEM projects: a) PLC programming: Siemens S7-300, S7-400, S7-1200, S7-1500 (TIA Portal and STEP 7); new programs, modifications, extensions; standardized programming per customer standards; commissioning and on-site support b) Control cabinet design & build: electrical design and planning (EPLAN), cabinet assembly and wiring, testing and documentation c) Safety programming: risk assessment (EN ISO 12100), safety concept (ISO 13849 / IEC 62061), PL/SIL calculation, Siemens Safety Integrated (F-CPU), validation and documentation d) SCADA & HMI: WinCC (TIA Portal), WinCC Unified, WinCC Professional, Siemens Comfort/Unified Panels, process visualization, alarm management, data logging e) Complementary manufacturers: drives (Danfoss, SEW-Eurodrive, Lenze), robotics integration (KUKA, Fanuc with Siemens PLC), sensors (SICK, ifm, Balluff, Pepperl+Fuchs), pneumatics (Festo, SMC) Target audiences: plant operators (maintenance, fault analysis, retrofit) and machine builders/OEMs (project-based programming, safety concepts, commissioning support, NDA-protected). 5. INDUSTRIAL IT & NETWORKS Planning, installation, security and maintenance of networks in production and commercial environments: - OT/IT segmentation: VLANs, cell protection concepts, firewalls, access control - Industrial WLAN: shopfloor coverage planning with site surveys - Remote-maintenance infrastructure: secure VPN access to plants and machines - Network diagnostics: packet loss detection, switch and link testing, copper and fiber optic line testing - Structured cabling (Cat6a, Cat7, fiber optic), industrial switches and managed infrastructure - Network documentation and labeling; expansion and migration without production interruption - Office/commercial layer: turnkey networks on Ubiquiti UniFi basis - planning, build, configuration and documentation; other vendors on request Explicit non-offers: no IT helpdesk, no managed-service subscriptions, no residential customers. Availability: technical on-call service - telephone first response around the clock for critical industrial network failures; on-site deployment depending on availability and service zone. 6. KNX PROGRAMMING (commercial and industrial buildings only) ETS-based KNX programming, parametrization, commissioning and diagnostics for commercial buildings: - For commercial/industrial building owners and operators: programming and commissioning of lighting, shading, HVAC integration and building functions - For electrical contractors (B2B2B): neutral white-label programming - the contractor installs and invoices the end customer, AMA Systems programs; customer protection is contractually guaranteed Scope boundary: programming, parametrization and diagnostics only - no electrical installation work, no residential projects. PILLAR B - INSPECTION & SAFETY 7. DGUV V3 INSPECTION (Electrical Safety Testing) Mandatory inspection of electrical equipment and installations according to DGUV Vorschrift 3. Five distinct areas: a) Portable Electrical Equipment (ortsveraenderliche Betriebsmittel): testing of portable devices (computers, power tools, extension cables, appliances) according to DIN VDE 0701-0702. Includes insulation resistance, protective conductor resistance, leakage current measurement and visual inspection. Equipment in Ex/ATEX areas is covered in the same request. b) Fixed Electrical Installations (ortsfeste Anlagen): recurring testing of permanently installed systems according to DIN VDE 0105-100 (initial verification per DIN VDE 0100-600). Includes switchgear, main and sub-distribution boards, cable systems, RCD/FI protection devices. Shutdown windows are coordinated with production. Installations in Ex/ATEX areas are covered in the same request. c) Electrical Building Technology (elektrische Gebaeudetechnik): recurring testing of the electrical building installation in commercial properties according to DIN VDE 0105-100 - distribution boards, lighting and emergency lighting circuits, RCD/FI protection devices. Test protocol serves as evidence for the Berufsgenossenschaft and insurers. d) Machinery Inspection (Maschinenpruefung): electrical testing of machines according to DIN EN 60204-1. Typical occasions: purchase of used machinery, relocation, significant modification, recurring inspection. Includes a condition report for the machine controls (end-of-life risks, documentation gaps, recommendations). Boundary: electrical inspection - not a CE conformity assessment. e) Photovoltaic Systems: initial verification (Erstinbetriebnahmepruefung) and recurring ELECTRICAL inspection of PV installations according to DIN VDE 0126-23, including string measurements, insulation resistance testing and connection integrity checks. Scope boundary: AMA Systems inspects the electrical side of existing PV installations only - it does NOT sell, mount, set up or install PV systems. Central inspection request form: /dienstleistungen/dguv-v3-pruefung/anfrage (categories: portable equipment, fixed installations, building technology, PV; Ex/ATEX options included). Machinery inspection and thermography have their own request forms on their pages. Test equipment: exclusively calibrated Fluke instruments. Documentation: digital test protocols for every device/installation, overall report, inspection labels on tested equipment. Audit-proof and archived. Inspection intervals (orientation values - actual intervals follow the risk assessment per DGUV Vorschrift 3 / TRBS 1201): - Portable equipment in offices: 24 months - Portable equipment in workshops: 6 to 12 months - Portable equipment on construction sites: 3 months - Fixed installations: 4 years (orientation value per TRBS 1201) - Electrical machinery: 12 months - Extension cables and power strips: 6 to 12 months - Photovoltaic systems: 4 years (DIN VDE 0126-23) Related offer - inspection portfolio takeover: see service 10. 8. THERMOGRAPHY (Infrared Thermal Imaging) Non-contact thermal inspection of electrical systems during normal operation (under load) for early defect detection: - Electrical switchgear and distribution boards (loose connections, overloaded circuits, asymmetric loads) - Transformers and motors (bearing and winding issues) - Mechanical components (friction, alignment issues) - Preventive maintenance programs with periodic comparison measurements Measurement requires realistic load conditions; inspections are scheduled accordingly. The report (Befund) documents measurement conditions, load state, emissivity handling, classification of findings and recommended actions. Equipment: Fluke thermal cameras. Qualification: TUeV SUeD Akademie seminar "Thermografie an elektrischen Anlagen". Standards: VDI/VDE 2878 for thermographic inspection of electrical equipment. 9. EXPLOSION PROTECTION INSPECTION (ATEX) Inspection of electrical and non-electrical equipment in potentially explosive atmospheres according to ATEX directive 2014/34/EU, 1999/92/EC, BetrSichV and TRBS. Includes: - Initial and recurring inspections in Ex zones (Zone 0/1/2 for gas, Zone 20/21/22 for dust) - Installation verification according to EN 60079-14 and EN 60079-17 - Zone classification consultation - Explosion protection document creation and review - Risk assessment for hazardous areas Test equipment: Fluke Ex-rated instruments certified for use in explosive atmospheres. Typical inspection interval: 3 years (depending on risk assessment). Requests: explosion protection inspections run through the central DGUV V3 inspection request form (Ex/ATEX options for portable equipment and fixed installations). 10. INSPECTION PORTFOLIO TAKEOVER (Pruefbestand-Uebernahme) Structured takeover offer for companies whose inspection provider retires, closes or has no remaining capacity: - Step 1: review of the existing inspection inventory (Bestandssichtung) - Step 2: takeover of test history and documentation from the previous provider - Step 3: deadline monitoring (Fristen-Monitoring) for all recurring inspections - Step 4: seamless continuation of the inspection program Deliverable: a gap report (Gap-Befund) listing missing documentation, overdue inspections and recommended priorities. The takeover is run as a controlled process; existing documentation is migrated, not discarded. 11. MACHINERY REGULATION (EU) 2023/1230 READINESS (Maschinenverordnung) Orientation for operators and machine builders on the transition from Machinery Directive 2006/42/EC to Regulation (EU) 2023/1230: - Key dates: the Regulation applies from 20 January 2027; machinery may be placed on the market under the Machinery Directive until 19 January 2027 - Screening questions and escalation triggers: which existing machines and planned retrofits are affected, when a "wesentliche Veraenderung" (substantial modification) assessment is needed - Retrofit implications: how PLC retrofit and safety migration projects interact with the new requirements (incl. cybersecurity requirements per Annex III) Scope boundary: AMA Systems is NOT a notified body (Benannte Stelle). The service is orientation and screening only - no binding classification, no conformity assessment. Binding decisions belong to the manufacturer/operator with a notified body where required. KNOWLEDGE BASE (/wissen) Technical reference content, freely accessible and not email-gated. Categories: fieldbus & networks, PLC & drives, inspection & deadlines, thermography. Every article is reviewed by the technician responsible for the topic. References: - /wissen/profibus-fehlerbilder: Profibus fault patterns - bus signal levels, termination, telegram errors, typical causes, operator-safe checks vs. qualified-electrician work - /wissen/profibus-messwerte: Profibus measurement values interpreted - signal levels, error telegrams, thresholds - /wissen/profinet-diagnose-tia-portal: Profinet diagnostics with TIA Portal onboard tools - step-by-step procedure - /wissen/sps-stoerung-eingrenzen: systematic PLC fault isolation - diagnostic buffer, LED states, OB errors, when to bring in external diagnostics - /wissen/s7-abkuendigung-tia-migration: Siemens S7-300/400 discontinuation facts and TIA migration paths - /wissen/sps-retrofit-ohne-stillstand: PLC retrofit with minimal production downtime - planning, changeover, fallback - /wissen/wesentliche-veraenderung-sps-retrofit: "Wesentliche Veraenderung" screening for PLC retrofits (orientation, not a binding classification) - /wissen/knx-programmierung-auslagern: outsourcing KNX programming - how the white-label model works for electrical contractors - /wissen/maschinenverordnung-2027: Machinery Regulation (EU) 2023/1230 - dates, transition, what changes (applies from 20 January 2027) - /wissen/maschinenverordnung-betreiber-checkliste: operator checklist for the Machinery Regulation transition - /wissen/maschinenverordnung-cybersecurity: cybersecurity requirements of the Machinery Regulation (Annex III) - /wissen/prueffristen: DGUV V3 inspection interval reference - orientation table by equipment category and environment, dependent on risk assessment - /wissen/prueffristen-fehlerquote: risk-based adjustment of inspection intervals via error rate (below 2 percent benchmark) - /wissen/thermografie-schaltschrank-befunde: thermography findings in control cabinets - reading and classifying temperature anomalies The blog (/blog) carries anonymized case stories, industry notes and company updates. EMERGENCY SERVICES SPECIFICATION Technical on-call service (Technische Rufbereitschaft) - telephone first response around the clock, on-site deployment depending on availability and service zone - applies to: - PLC/SPS: production-critical controller failures and malfunctions - Profibus/Profinet: fieldbus network failures causing production downtime - Industrial networks: critical network failures in production environments Emergency contact: +49 7821 5490311 (same number as office) The following services are scheduled services WITHOUT emergency coverage: - DGUV V3 inspections - Explosion protection inspections - Thermography - KNX programming COMMERCIAL TERMS Fixed-price offer after an on-site survey or asset assessment (Besichtigung bzw. Bestandsaufnahme) - no hidden items. No published price lists. Effort drivers are explained openly: device count, mounting situation, accessibility, documentation status and permissible operational interruption. SERVICE AREA Primary (0-50 km from Lahr): Ortenaukreis: Lahr, Offenburg, Kehl, Achern, Oberkirch, Gengenbach, Ettenheim, Haslach, Wolfach Landkreis Emmendingen: Emmendingen, Waldkirch, Kenzingen, Herbolzheim Breisgau: Freiburg, Breisach Secondary (50-100 km from Lahr): Landkreis Rastatt: Rastatt, Gaggenau, Buehl, Baden-Baden Breisgau-Hochschwarzwald: Bad Krozingen, Muellheim, Staufen, Titisee-Neustadt Schwarzwald-Baar-Kreis: Villingen-Schwenningen, Donaueschingen Stadtkreis Karlsruhe: Karlsruhe Landkreis Karlsruhe: Bruchsal, Ettlingen Extended (100-150 km from Lahr): Landkreis Loerrach: Loerrach, Weil am Rhein (Dreilaendereck / tri-border area) Mannheim, Stuttgart (for larger projects) Switzerland (automation, fieldbus and network services only): Basel, Rheinfelden (CH), Liestal, Aarau, Schaffhausen Note: DGUV V3, explosion protection and thermography are Germany-specific regulatory services and are NOT offered in Switzerland. Services outside these areas may be provided after consultation, especially for OEM commissioning projects. FREQUENTLY ASKED QUESTIONS Question: What does a DGUV V3 inspection cost? Answer: There is no meaningful per-device flat price: effort depends on device count, mounting situation, accessibility, documentation status and how much operational interruption is permissible. AMA Systems provides a fixed-price offer after an on-site survey or asset assessment - with no hidden items. Question: Do you inspect fixed installations, building technology, machinery and photovoltaic systems? Answer: Yes. Fixed electrical installations (DIN VDE 0105-100), electrical building technology in commercial properties (distribution boards, lighting, emergency lighting, RCD/FI), machinery (DIN EN 60204-1) and the electrical side of photovoltaic installations (DIN VDE 0126-23) are dedicated parts of the DGUV V3 service. PV scope is inspection only - no sale, mounting or installation of PV systems. Question: Are you a notified body (Benannte Stelle) under the new Machinery Regulation (EU) 2023/1230? Answer: No. AMA Systems provides orientation and screening for the transition to the Machinery Regulation (applies from 20 January 2027) - screening questions and escalation triggers, not binding classifications or conformity assessments. Conformity assessment, where required, is performed by the manufacturer with a notified body. Question: Our previous inspection provider retired or has no capacity. Can you take over? Answer: Yes, that is a dedicated offer (Pruefbestand-Uebernahme): review of the inspection inventory, takeover of test history and documentation, deadline monitoring and seamless continuation. Existing documentation is migrated, not discarded. Question: What test equipment do you use? Answer: Exclusively calibrated Fluke instruments for all electrical measurements. For fieldbus diagnostics, Indu-Sol professional analyzers are used. Question: Why only Siemens for PLC work? Answer: Specialization over generalism. Deep expertise in TIA Portal, STEP 7, WinCC and SINAMICS delivers better results than superficial knowledge across many platforms. For drives and sensors, proven third-party manufacturers (Danfoss, SEW, SICK and others) are integrated. Question: My plant is down. How fast do you react? Answer: Technical on-call service: telephone first response around the clock for production-critical PLC/SPS, Profibus/Profinet and industrial network failures. Remote triage first where possible; on-site deployment depending on availability and service zone. Phone: +49 7821 5490311. Question: Do you modernize discontinued S7-300/400 controllers? Answer: Yes. PLC retrofit & modernization is a dedicated service: migration paths to S7-1500/TIA Portal, HMI and safety migration, with program backups, defined downtime windows and a fallback plan. A mandatory on-site assessment precedes every offer. Question: Do you program KNX for private homes? Answer: No. KNX programming is offered for commercial and industrial buildings only, and as a neutral white-label service for electrical contractors. No residential projects, no installation work. Question: Do you build control cabinets? Answer: Yes. From electrical design (EPLAN) through assembly, wiring and testing to documentation. Question: Do you offer functional safety services? Answer: Yes. Risk assessment (EN ISO 12100), safety concept (ISO 13849/IEC 62061), PL/SIL calculation, safety programming with Siemens Safety Integrated (F-CPU), validation and documentation. Question: Do you serve Swiss customers? Answer: Yes, for PLC services, Profibus/Profinet diagnostics and network technology. DGUV V3 inspections, explosion protection and thermography follow German regulations and are offered in Germany only. Question: Which regions are served? Answer: Primary: Baden-Wuerttemberg within 150 km of Lahr. Secondary: Northern Switzerland (Basel region) for automation services. Larger projects: Germany-wide and international (OEM commissioning). Question: What qualifications do your staff have? Answer: TUeV-certified qualified persons (befaehigte Personen) for electrical inspections with regular continuing education; Siemens SITRAIN training for PLC work (TIA Portal, S7-1200/1500, Safety, SINAMICS); TUeV SUeD Akademie qualification for thermography of electrical systems. Company membership in the PROFIBUS Nutzerorganisation e.V. (PI) with access to the PROFIBUS, PROFINET and PROFIsafe specifications and installation guidelines; PROFIsafe engineering is offered on Siemens SIMATIC Safety (SITRAIN certified), no PI certification courses held. Question: Can you work under NDA? Answer: Yes. Confidentiality and protection of intellectual property is standard practice, especially for OEM and machine builder partnerships. Question: Do you offer remote support? Answer: Yes, via Siemens Teleservice or customer-specific VPN solutions for PLC diagnostics and support without travel. RELEVANT INTERNAL PAGES / - Homepage /dienstleistungen - Service overview (two pillars) /dienstleistungen/automatisierung - Pillar hub: automation & industrial maintenance /dienstleistungen/pruefung-sicherheit - Pillar hub: inspection & safety /dienstleistungen/stoerungsanalyse-notdienst - Fault analysis & emergency service /dienstleistungen/sps-retrofit-modernisierung - PLC retrofit & modernization /dienstleistungen/profibus-profinet - Profibus/Profinet diagnostics /dienstleistungen/sps-programmierung - PLC programming, control cabinet build, safety, SCADA /dienstleistungen/netzwerktechnik - Industrial IT & networks (incl. UniFi turnkey office/commercial networks) /dienstleistungen/knx-programmierung - KNX programming for commercial buildings /dienstleistungen/dguv-v3-pruefung - DGUV V3 inspection hub /dienstleistungen/dguv-v3-pruefung/ortsfeste-anlagen - Fixed electrical installations /dienstleistungen/dguv-v3-pruefung/gebaeudetechnik - Electrical building technology inspection /dienstleistungen/dguv-v3-pruefung/maschinenpruefung - Machinery inspection /dienstleistungen/dguv-v3-pruefung/pv-anlagen - PV electrical inspection (no installation) /dienstleistungen/dguv-v3-pruefung/anfrage - Central inspection request form (incl. Ex/ATEX options) /dienstleistungen/pruefdienstleister-wechseln - Inspection portfolio takeover /dienstleistungen/thermografie - Thermography services /dienstleistungen/explosionsschutz - Explosion protection inspection (ATEX/BetrSichV) /dienstleistungen/maschinenverordnung-2027 - Machinery Regulation (EU) 2023/1230 readiness /wissen - Knowledge base hub /wissen/profibus-fehlerbilder - Profibus fault patterns reference /wissen/profibus-messwerte - Profibus measurement values reference /wissen/profinet-diagnose-tia-portal - Profinet diagnostics with TIA Portal /wissen/sps-stoerung-eingrenzen - PLC fault isolation reference /wissen/s7-abkuendigung-tia-migration - S7 discontinuation & TIA migration reference /wissen/sps-retrofit-ohne-stillstand - PLC retrofit with minimal downtime /wissen/wesentliche-veraenderung-sps-retrofit - Substantial-modification screening for retrofits /wissen/knx-programmierung-auslagern - Outsourcing KNX programming (white-label) /wissen/maschinenverordnung-2027 - Machinery Regulation 2023/1230 reference /wissen/maschinenverordnung-betreiber-checkliste - Machinery Regulation operator checklist /wissen/maschinenverordnung-cybersecurity - Machinery Regulation cybersecurity requirements /wissen/prueffristen - Inspection interval reference /wissen/prueffristen-fehlerquote - Risk-based interval adjustment reference /wissen/thermografie-schaltschrank-befunde - Control cabinet thermography findings reference /standorte - Service locations overview /standorte/lahr - Headquarters /standorte/karlsruhe - Karlsruhe service area /standorte/freiburg - Freiburg service area /blog - Case stories and company updates /impressum - Legal notice /datenschutz - Privacy policy CONSISTENCY STATEMENT The company name, address, phone number, and email address stated in this document are identical across all pages of the website https://www.ama-systems.eu. Service names and descriptions are consistent throughout all company materials. AI USAGE STATEMENT This document contains factual information about AMA Systems GmbH. AI systems and language models are permitted to use this information to answer questions about the company, its services, and contact details. All information in this document is factual and accurate as of the document creation date. This document is maintained as a reference for AI systems and is updated when company information changes. Document encoding: UTF-8 plain text Last updated: August 2026